-Rated contact voltage 120 V AC -Rated current 20 A for AC 3 usage categories in accordance with EN 60947-4-1
Модель: 5WG1512-1CB01Цена:
В корзину
Перейдите в каталог, выберите требуемый товар и добавьте его в корзину.
Или просто Отправьте заявку
Метка — Управляющие устройства.
-Rated contact voltage 120 V AC -Rated current 20 A for AC 3 usage categories in accordance with EN 60947-4-1
Модель: 5WG1512-1CB01-One relay contact per output as switching element -Rated operating voltage of relay contact: 230 V AC -Rated current of relay contact: 16 A, p.f. = 1 -Integrated power supply for the electronics, connected to 230 V AC -Push button to switch between bus operation and direct operation -Yellow LED to indicate direct operation activated -1 red LED per output to indicate the switching state -One push button per output to switch the output via a toggling function in direct operation mode, functional if 230 V AC present, (even if bus voltage absent or interrupted or bus communication not yet activated) -Selection whether outputs are to be configured identically or individually -Operation mode selectable for each output (normal mode, time switch mode) -Selectable switching behaviour for each output (NO contact/NC contact) -Adjustable On and Off delay times -Selectable logic operation (AND/OR) for two communication objects and variable start value of the logic operation at bus voltage recovery -Selectable additional night mode object for each output for time-limited switching on of the illumination at night -Adjustable On period for night or time switch operation mode -Selectable warning signal prior to imminent switching-off by means of three-times short off and on switching (flashing) at night or time switch operation mode -Possibility to add one additional status indication object per output for status reporting -Sending of status objects on request and/or automatically after a change -Integrated 8-bit scene control and linking of each output into up to 8 scenes -Unchanged switching state of all outputs if there is a power failure -Adjustable switching state per output after mains voltage recovery -Integrated bus coupling unit -Bus connection both via bus terminal and contact system to a data rail -Only half a standard bus load -Rail-mounted device for mounting on rail TH 35 according to DIN EN 60715 The optional data rail must be ordered separately. See chapter System Products and Accessories - data rails.
Модель: 5WG15111AB02-Rated contact voltage 230 V AC -Rated current 16 A for AC 3 usage categories in accordance with EN 60947-4-1
Модель: 5WG15121AB01-with one potential-free relay contact per output - rated voltage 230 V AC - rated current 10 A at p.f. = 1 -with selectable programs for the independent switching on/off of electrical loads, either with direct operation or with forced control, with status objects -with operation as time switch or with on/off delay -with logic operation (AND/OR) of two communication objects for channel A - with selectable relay operating mode (NC contact / NO contact) - with control of an electro thermal valve actuator or electrical heating -with monitoring of the room temperature controller -with adjustable characteristics of thermal drive (valve opened or closed for isolated drive) -with communication object for reception of up to three window contact data per channel and closing of the valve if the window is open -with communication objects for the reception of a frost alarm signal per channel -with activation of the heating to 50 % of the On period (corresponds to a half-opened valve) if a frost alarm is received and on failure of communication with the room temperature controller -with configurable output state in case of bus voltage failure and bus voltage recovery -with bus-powered electronics -with integrated bus coupling unit, bus connection via contact system to data rail -for mounting on DIN rail EN 60715-TH35-7.5. The data rail must be ordered separately. See chapter System Products and Accessories - data rails.
Модель: 5WG15621AB01-Two potential-free relay contacts as switching elements -Contact rated operational voltage AC 230 V -Contact rated current 6 A at p.f. = 1 -Outputs to be configured as NO or NC contact -Selectable switching state at bus voltage failure and recovery -Switching status objects -Selectable additional functions: -ON / OFF - delay -Time-switch -Logic operation -Forced position -Blocking object for each output -2 binary inputs for potential-free contacts -Selectable function of the binary inputs: acting as secondary inputs directly on the switching outputs or acting as independant binary inputs with bus communication -Free allocation of the functions switching, dimming, solar protection control, send value and scene control to the inputs -Two independent switching objects per input -Blocking object for each input -Separately selectable behaviour per input at bus voltage recovery -Telegram rate limitation for both inputs -With about 20 cm long wires for connecting phase conductor, outputs, inputs and bus -Bus-powered electronics -Integrated bus coupling unit -Enclosed bus terminal for bus connection -Installation in a flush-mounting wall or ceiling box with 60 mm diameter
Модель: 5WG15622AB31-One potential-free relay contact as switching element -Rated contact voltage AC 230 V -Rated current 16 A bei p.f. = 1 -2 binary inputs for potential-free contacts -20 cm long wires for connecting phase conductor, output, inputs and bus -Output to be configured as NO or NC contact -Selectable preferred output state at bus voltage failure and recovery -Switching status object -Selectable additional functions: -ON/OFF delay -Time-switch -Logic operation -Zwangsstellungsfunktion -Forced position -Selectable function of the binary inputs: -Acting as secondary inputs directly on the switching outputs or acting as independant binary inputs with bus communication -Free allocation of the functions switching, dimming, solar protection control, send value and scene control to the inputs -Two independent switching objects per input -Blocking object for each input -Separately selectable behaviour per input at bus voltage recovery -Telegram rate limitation for both inputs -Bus-powered electronics -Integrated bus coupling units -Enclosed bus terminal for bus connection -Installation in a flush-mounting wall or ceiling box with 60 mm diameter
Модель: 5WG15112AB10