Rated contact current 16 AX
Модель: 5WG15121AB11Цена:
В корзину
Перейдите в каталог, выберите требуемый товар и добавьте его в корзину.
Или просто Отправьте заявку
Метка — Gamma instabus - KNX.
-with one potential-free relay contact per output - rated voltage 230 V AC - rated current 10 A at p.f. = 1 -with selectable programs for the independent switching on/off of electrical loads, either with direct operation or with forced control, with status objects -with operation as time switch or with on/off delay -with logic operation (AND/OR) of two communication objects for channel A - with selectable relay operating mode (NC contact / NO contact) - with control of an electro thermal valve actuator or electrical heating -with monitoring of the room temperature controller -with adjustable characteristics of thermal drive (valve opened or closed for isolated drive) -with communication object for reception of up to three window contact data per channel and closing of the valve if the window is open -with communication objects for the reception of a frost alarm signal per channel -with activation of the heating to 50 % of the On period (corresponds to a half-opened valve) if a frost alarm is received and on failure of communication with the room temperature controller -with configurable output state in case of bus voltage failure and bus voltage recovery -with bus-powered electronics -with integrated bus coupling unit, bus connection via contact system to data rail -for mounting on DIN rail EN 60715-TH35-7.5. The data rail must be ordered separately. See chapter System Products and Accessories - data rails.
Модель: 5WG15621AB01-Two potential-free relay contacts as switching elements -Contact rated operational voltage AC 230 V -Contact rated current 6 A at p.f. = 1 -Outputs to be configured as NO or NC contact -Selectable switching state at bus voltage failure and recovery -Switching status objects -Selectable additional functions: -ON / OFF - delay -Time-switch -Logic operation -Forced position -Blocking object for each output -2 binary inputs for potential-free contacts -Selectable function of the binary inputs: acting as secondary inputs directly on the switching outputs or acting as independant binary inputs with bus communication -Free allocation of the functions switching, dimming, solar protection control, send value and scene control to the inputs -Two independent switching objects per input -Blocking object for each input -Separately selectable behaviour per input at bus voltage recovery -Telegram rate limitation for both inputs -With about 20 cm long wires for connecting phase conductor, outputs, inputs and bus -Bus-powered electronics -Integrated bus coupling unit -Enclosed bus terminal for bus connection -Installation in a flush-mounting wall or ceiling box with 60 mm diameter
Модель: 5WG15622AB31-One potential-free relay contact as switching element -Rated contact voltage AC 230 V -Rated current 16 A bei p.f. = 1 -2 binary inputs for potential-free contacts -20 cm long wires for connecting phase conductor, output, inputs and bus -Output to be configured as NO or NC contact -Selectable preferred output state at bus voltage failure and recovery -Switching status object -Selectable additional functions: -ON/OFF delay -Time-switch -Logic operation -Zwangsstellungsfunktion -Forced position -Selectable function of the binary inputs: -Acting as secondary inputs directly on the switching outputs or acting as independant binary inputs with bus communication -Free allocation of the functions switching, dimming, solar protection control, send value and scene control to the inputs -Two independent switching objects per input -Blocking object for each input -Separately selectable behaviour per input at bus voltage recovery -Telegram rate limitation for both inputs -Bus-powered electronics -Integrated bus coupling units -Enclosed bus terminal for bus connection -Installation in a flush-mounting wall or ceiling box with 60 mm diameter
Модель: 5WG15112AB10-LED for status indication or configurable as orientation light -Single, pushbutton position
Модель: 5WG11153AB21-Brightness measurement, temperature measurement, sun protection control, lighting control -For the detection and transmission of brightness and temperature -Temperature measuring range -25 °C...+55 °C -Brightness measuring range 1 Lux...100 kLux -Horizontal sensing angle -60°...+60°, vertical -35°...+66.5° -For the control of switch, dimming and shutter/blind actuators, depending on the ambient luminosity and/or ambient temperature -One sun protection channel for the automatic control of sun protection equipment, with -Starting and stopping of automation by means of an object or a dusk threshold -Up to three brightness thresholds for determining the height and position of the shutters/blinds or roller shutters -Optional teach-in of dusk thresholds and brightness thresholds by means of a teach-in facility -Blocking object for the temporary deactivation of the sun protection channel function -Up to four universal channels for the control of switch, dimming and shutter/blind actuators, depending on ambient luminosity and/or temperature. Optionally available with: -Threshold switches for brightness -Threshold switches for temperature -Threshold switches with logical combination of brightness and temperature -Optional teach-in of brightness threshold for each universal channel by means of an associated teach-in facility -Deactivation option for each universal channel by means of an associated blocking object (1 bit) -Optional second object for transmission of a second telegram on fulfillment of threshold conditions -Bus-powered electronics -Integrated bus coupling units -Bus connection via bus terminal -Surface mounting -Degree of protection: IP54 Light level control modules N 342 see chapter Lighting - Light level controls
Модель: 5WG12543EY02-Windspeed Measuring range 0...35 m/s -Recording, querying and resetting the maximum wind speed -Automatic indication in the event of a defective sensor -Mast mountings -Limit value monitoring (3 limit values) -Transmission of sensor values via bus -Logic operations (8 AND, 8 OR) -Electronics powered via an external power supply unit -Integrated bus coupling units, bus connection via bus terminal -Surface mounting, degree of protection IP44 The 4AC2402 electronic power supply unit is recommended.
Модель: 5WG12573AB42-Opening alarm for the monitoring of windows and doors, comprising: -1 magnet (? 8 x 30 mm) -1 magnetically operated contact in a fully cast plastic enclosure (? 8 x 30 mm) -Switching voltage: max. 110 V DC -Switching current: 10...100 mA -Contact current carrying capacity: max. 5 W -Contact resistance: max. 150 mW -VdS-class B -5 m long connection cable LiYY 4 x 0,14 mm2 -Suitable for flush and surface mounting -2 surface-mounting enclosure tops (43 x 12 x 12 mm) -2 surface-mounting enclosure bottoms -4 spacer plates (thickness: 2 x 4 mm or 2 x 2 mm) -2 flush-mounting flanges -4 antimagnetic countersunk self-tapping screws DIN 7982-ST2, 9 x 16-A2
Модель: 5WG12907AB11-Opening alarm for the monitoring of windows and doors, comprising: -1 magnet (? 8 x 30 mm) -1 magnetically operated contact in a fully cast plastic enclosure (? 8 x 30 mm) -Switching voltage: max. 110 V DC -Switching current: 10...100 mA -Contact current carrying capacity: max. 5 W -Contact resistance: max. 150 mW -VdS-class B -5 m long connection cable LiYY 4 x 0.14 mm2 -Suitable for flush and surface mounting -2 surface-mounting enclosure tops (43 x 12 x 12 mm) -2 surface-mounting enclosure bottoms -4 spacer plates (thickness: 2 x 4 mm or 2 x 2 mm) -2 flush-mounting flanges -4 antimagnetic countersunk self-tapping screws DIN 7982-ST2, 9 x 16-A2
Модель: 5WG12907AB81