Rated contact current 16 AX
Модель: 5WG15121AB21Цена:
В корзину
Перейдите в каталог, выберите требуемый товар и добавьте его в корзину.
Или просто Отправьте заявку
-with one potential-free relay contact per output - rated voltage 230 V AC - rated current 10 A at p.f. = 1 -with selectable programs for the independent switching on/off of electrical loads, either with direct operation or with forced control, with status objects -with operation as time switch or with on/off delay -with logic operation (AND/OR) of two communication objects for channel A - with selectable relay operating mode (NC contact / NO contact) - with control of an electro thermal valve actuator or electrical heating -with monitoring of the room temperature controller -with adjustable characteristics of thermal drive (valve opened or closed for isolated drive) -with communication object for reception of up to three window contact data per channel and closing of the valve if the window is open -with communication objects for the reception of a frost alarm signal per channel -with activation of the heating to 50 % of the On period (corresponds to a half-opened valve) if a frost alarm is received and on failure of communication with the room temperature controller -with configurable output state in case of bus voltage failure and bus voltage recovery -with bus-powered electronics -with integrated bus coupling unit, bus connection via contact system to data rail -for mounting on DIN rail EN 60715-TH35-7.5. The data rail must be ordered separately. See chapter System Products and Accessories - data rails.
Модель: 5WG15621AB01-Two potential-free relay contacts as switching elements -Contact rated operational voltage AC 230 V -Contact rated current 6 A at p.f. = 1 -Outputs to be configured as NO or NC contact -Selectable switching state at bus voltage failure and recovery -Switching status objects -Selectable additional functions: -ON / OFF - delay -Time-switch -Logic operation -Forced position -Blocking object for each output -2 binary inputs for potential-free contacts -Selectable function of the binary inputs: acting as secondary inputs directly on the switching outputs or acting as independant binary inputs with bus communication -Free allocation of the functions switching, dimming, solar protection control, send value and scene control to the inputs -Two independent switching objects per input -Blocking object for each input -Separately selectable behaviour per input at bus voltage recovery -Telegram rate limitation for both inputs -With about 20 cm long wires for connecting phase conductor, outputs, inputs and bus -Bus-powered electronics -Integrated bus coupling unit -Enclosed bus terminal for bus connection -Installation in a flush-mounting wall or ceiling box with 60 mm diameter
Модель: 5WG15622AB31-One potential-free relay contact as switching element -Rated contact voltage AC 230 V -Rated current 16 A bei p.f. = 1 -2 binary inputs for potential-free contacts -20 cm long wires for connecting phase conductor, output, inputs and bus -Output to be configured as NO or NC contact -Selectable preferred output state at bus voltage failure and recovery -Switching status object -Selectable additional functions: -ON/OFF delay -Time-switch -Logic operation -Zwangsstellungsfunktion -Forced position -Selectable function of the binary inputs: -Acting as secondary inputs directly on the switching outputs or acting as independant binary inputs with bus communication -Free allocation of the functions switching, dimming, solar protection control, send value and scene control to the inputs -Two independent switching objects per input -Blocking object for each input -Separately selectable behaviour per input at bus voltage recovery -Telegram rate limitation for both inputs -Bus-powered electronics -Integrated bus coupling units -Enclosed bus terminal for bus connection -Installation in a flush-mounting wall or ceiling box with 60 mm diameter
Модель: 5WG15112AB10-LED for status indication or configurable as orientation light -Single, pushbutton position
Модель: 5WG11153AB214 Inputs for 230 V AC with shared ground (N) The data rail must be ordered separately. See chapter System Products and Accessories - Data rails.
Модель: 5WG12601AB01